Ali Musyafa, Heri Joestiono, Yaumar : Heating Test at Household Refrigerator Type URG-129 Base Standard Nasional Indonesia (SNI) 04-6292.2.24-2001 for Safety Requirement

Dr.Ir. Ali Musyafa M.Sc.
Ir. Heri Joestiono MT
Ir. Yaumar MT.

Year

-

Published in

Asian Journal of Natural & Applied Sciences

External link

Type

Jurnal Internasional

Keywords

Heating-test;refrigerators;Indonesian-National-Standard;passed-the-test;


Abstract

Electrical appliance safety assurance is needed. In the electrical equipment in refrigerator URG-129 brand UCD Indonesian products required test activities increase the heat to determine the feasibility of the use. Standards referenced in the testing technique are the Indonesian National Standard (SNI-04-6292.2.24). The test results showed that the level of flatness of the temperature distribution occurs in the working area (2.8 0.5) C to (10.8 0.4) C and when setting thermostat in normal position with the cooling load of 16 liters. Ice maker room temperature refrigerant URG-129 is always above 0 C, then refrigerator not qualify heating test. Setting thermostat on hree conditions, normal, cold and very cold, refrigerator cannot meet the test SNI requirement, ice maker refrigerator room temperature is always above 0 C.